The following product line is being discontinued. A recommended replacement is shown at:

AC or DC control input solid state relays for switching AC loads

Potentiometer input, 25 or 35 amp, 3 phase din rail power controller

Features

  • Allows a customer to dial in a request from 0% to 100% power.
  • Accepts a standard potentiometer input and provides a high speed, time proportional AC output (TPO). That is a zero-crossing, "no electronic noise", power control signal that is ideal for resistive heaters, heat sealing bars, injection molding nozzle zones, simple cookers, etc.
  • Output cycle time ("ON" time + "OFF" time) = approximately 0.5 second at 50%. Output resolution is one half of one sinewave (8.3 msec for 60 hz applications).

Note: Rapid pulsing of the heaters provides the most precise temperature control, PLUS it dramatically increases the life of the heaters due to a reduction in the thermal stress of expansion and contraction.

  • A standard 0-5k potentiometer can be mounted anywhere on the machine.
  • Any standard 24 volt DC power supply can be used, such as your existing PLC power supply.
  • A 680 ohm, 5%, 1/2 watt resistor is installed in series.
  • A 6.8k ohm, resistor is installed in parallel.
  • A green LED shows input status on the power controller
  • Zero crossing activation -- low EMI, low noise to nearby electronics
  • Available for the DMA3-6V75T, three phase solid state contactor
  • UL, CSA, CE
DMA3 pot input
Three phase, 25 or 35 amps per leg, din rail contactor

Features

  • Maximum Surge Survival™ technology -- triple layer, voltage surge protection
  • Green LED for input status
  • Thermally optimized heat sink permits edge-to-edge installations on a din rail
  • Built-in snubber circuit
  • Zero crossing activation -- low EMI, low noise to nearby electronics
  • Internal 50A thyristors for high inrush capability
  • 4000 volt isolation, 1400Vpk blocking voltage
 
  • 1000 volt / microsecond immunity
  • Highest thermal efficiency -- less than 1.2 watts per amp switched, per leg
  • CE, UL recognized, CSA
  • Industry standard A1, A2, L1, T1, L2, T2, L3, T3 terminal numbers
  • High density design permits more amps per square inch
  • 3Ø = 25 amps per leg, 2Ø using L1/T1 and L3/T3 = 35 amps per leg.
  • Optional: 3 internal MOVs for a fourth layer of surge survival
DMA3 solid state contactors
DDA temperature curver

Part Numbers

Customer to supply the 0-5k pot, resistors, and 24 VDC power supply.

DMA3-6V75T   up to 75 amps TOTAL; 25A on three legs or 35A on 2 legs; 660V max, 4-20mA analog input activated Buy

DMA3-5V75T   up to 75 amps TOTAL; 25A on three legs or 35A on 2 legs; 575V max; 3 internal MOVs; 4-20mA analog input activated. Non-standard model -- consult factory for price and availability.


  
DDA size
DDA size


Specifications

Part Number Line Voltage Range (VAC) Load Current Range (A RMS) Max Voltage Drop @ 20mA
 
4-20mA analog input activated
DMA3-6V75T  24-660 .10-25 (3 leg) or 35 (2 leg) 10 VDC
DMA3-5V75T 24-575 .10-25 (3 leg) or 35 (2 leg) 10 VDC
 
Installation The DMA3 can be installed on a din rail or directly on a metal panel. The heat sink must be installed so the air flows up and through the fins.
Off-State dv/dt 1000 v/µs
Isolation 4000 volts isolation
I²T fuse 50A or less, for example: Bussman FWP50A14F, FWC32A10F, FWC20A10F. Ferraz Shawmut B093910, M330015, K330013
Example of control 0% = heater or load is "off"
50% = heater "on" 250 mseconds, "off" 250 msec, "on" 250 msec...
75% = "on" 375 msec, "off" 125msec, "on" 375 msec....
85% = "on" 425 msec, "off" 75msec, "on" 425 msec....
100% = heater "on"

Since the contactor is switching at the zero crossing mark of a sinewave, there is no electrical noise that might interfere with nearby electronics. Also, since the calculated ON or OFF time period is measured in half sine waves, the contactor will automatically adjust the total cycle time in order to maintain the best ratio of ON/OFF to match your control input.
Turn-on time <8.3 ms at 60hz
Turn-off time <8.3 ms at 60hz
Power terminals Will accept #24-#10 AWG wire. Torque: 7-9 inch lbs.
Control terminals Will accept #24-#14 AWG wire. Torque: 4 inch lbs.
Internal MOVs The "5V" models have three internal MOVs installed providing a fourth layer of surge survivial. Using the MOVs limits the product to applications from 48 - 575 volts.
Terminology The word "leg" refers to a switched AC power line. A three phase application may use 3 switched lines or 2 switched lines.